MEDICAL NB · Based on S Series (SQN)

Dental Unit Waterline Hygiene System MEDICAL NB

A compact inline system that supplies oxygen nanobubble water to the water lines of dental unit chairs. Linked to the existing water supply, it is applied to waterline hygiene management and can supply multiple unit chairs.

  • Unit chair waterlines
  • Oxygen nanobubbles
  • Ultra-compact
Treatment flow rate
0.5–3.0 L/min
Operating pressure
3.5–4.0 bar
Chairs connected
Up to 20
Gas used
Oxygen (built-in generator)

Tell us the number of chairs and your water supply method, and we will propose a suitable configuration.

Waterline hygiene linked to the existing water supply

Benefits dental clinics can expect, based on the properties of oxygen nanobubble water. Actual effects vary with water quality, waterline condition and conditions of use.

Dental treatment room being prepared

Less waterline maintenance work

Because oxygen nanobubble water flows through the waterlines during treatment, the separate time and effort spent on waterline maintenance can be reduced.

Glass of clear water

Optimized chemical use

Its supplementary use can be evaluated by reviewing compatibility with existing disinfection procedures and water quality standards.

Unit chair handpiece

Equipment care

The potential to manage contamination and deposits inside the waterlines can be reviewed as a way to support stable maintenance of the water system.

Patient in the dental chair with dental staff

Patient confidence

Clinics can explain to patients that they manage waterline hygiene consistently.

For dental unit chair water systems

Connects to the unit chair water line. We check the number of chairs and water supply method to recommend a suitable configuration.

  • Treatment room at a dental clinic

    Dental clinics

    Several chairs served by one unit

  • Dental hospital with several chairs

    Dental hospitals

    Installed per floor or treatment area

  • Hospital medical equipment

    Medical equipment waterlines

    Water lines of low-flow medical equipment that uses water

When MEDICAL NB is a good fit

  • Clinics with several chairs where waterline maintenance takes considerable time
  • Clinics aiming to reduce their use of chemical disinfectants
  • Clinics that want stable results from regular water quality tests
  • Treatment rooms with little space for equipment (ultra-compact configuration)
  • Treatment areas with up to 20 chairs (one unit serves up to 20, controlled by timer)

When another option is needed

  • For more than 20 chairs, the system is divided into zones with two or more units; please contact us
  • Irrigation and cooling water for surgical procedures should be sterile water or sterile saline in line with infection control guidelines
  • For waterlines that have not been maintained for a long time, their condition is checked before installation and, if needed, the lines are cleaned first

Compact inline system based on oxygen nanobubbles

An ultra-compact system connected to the water line supplies oxygen nanobubble water to multiple chairs.

Oxygen-enriched nanobubble water

The SQN bubble mixer dissolves oxygen and produces nanobubble water, which is supplied to the unit chair water system.

No chemicals added

Only water and oxygen are used. With no taste, color or odor, the water can be used as is for treatment and rinsing.

Ultra-compact, plug-in installation

Connects inline to the unit chair water line. Small enough for compact treatment rooms.

Up to 20 chairs per unit

Supply time is controlled by a timer so one unit can serve multiple chairs.

Patented technology and field application

Our patented waterline hygiene technology is being applied at dental clinics.

Swipe left or right to see the full table.

MEDICAL NB evidence and field application
Item Details Evidence
Patents Waterline hygiene management system for medical and dental use · Korean Patent No. 10-2816842 (registered May 30, 2025) Registered patent
Treated water dissolved oxygen 65–100 mg/L In-house test · Measured
Dental clinic field pilots Installed and operating at 3 clinics in Korea Pilot test · Validation planned

Results vary with source water quality, waterline condition and conditions of use. Used together with existing infection control procedures such as flushing before treatment and regular water quality tests.

Waterline water quality standards (reference)

Heterotrophic bacteria standards for dental unit water, confirmed by regular water quality testing.

Korea

Heterotrophic bacteria ≤100 CFU/mL · recommendation for dental unit water based on drinking water standards

US CDC

Heterotrophic bacteria ≤500 CFU/mL · standard for dental unit water in non-surgical procedures

Installation linked to the dental water line

Source water from the supply line is treated with nanobubbles and delivered to each unit chair's waterlines. The same water supplies handpieces, scalers, syringes and the rinse cup.

Swipe left or right to see the full table.

MEDICAL NB installation diagram Water from the supply line enters the unit and, with oxygen from the built-in oxygen generator, passes through the ultra-compact pump and SQN bubble mixer to become oxygen nanobubble water, which is distributed to the waterlines of multiple unit chairs. Power supply 220 V outlet Water supply line Mains water · purified water MEDICAL NB Built-in oxygen generator Ultra-compact pump + SQN bubble mixer Timer control Oxygen nanobubble water Unit chair 1 Handpiece · scaler · syringe · rinse cup Unit chair 2 Handpiece · scaler · syringe · rinse cup ⋯ up to 20 chairs Supply time set by timer
Concept diagram. The water supply line and unit chairs are existing equipment. Actual configuration and layout depend on the number of chairs and water supply method.
  1. Connection

    The unit is connected between the water supply line and the unit chairs.

  2. Nanobubble water generation

    The ultra-compact pump and SQN bubble mixer dissolve oxygen in the water to produce nanobubble water.

  3. Supply

    Nanobubble water is sent to each chair's waterlines according to the timer settings.

MEDICAL NB Specifications

The configuration is confirmed after checking the number of chairs and water supply method.

MEDICAL NB Specifications
Item MEDICAL NB
Base series S Series Compact Nanobubble System (SQN)
Type Ultra-compact pump + SQN bubble mixer, connected to the unit chair water line
Treatment flow rate 0.5–3.0 L/min
Operating pressure 3.5–4.0 bar
Gas used Oxygen (built-in oxygen generator)
Treated water dissolved oxygen 65–100 mg/L
Chairs connected Up to 20 (timer controlled)
Power supply 220 V single-phase
Unit dimensions 600 L × 180 W × 500 H mm

Standard specifications. For configurations tailored to your number of chairs and water supply method, please contact us.

Scope of supply, from technical consultation to delivery and installation

Supplied as an ultra-compact integrated unit combining the pump, bubble mixer and oxygen generator. Give us four pieces of information and we will recommend a suitable configuration and quote.

Included

  • Main unit · ultra-compact pump combined with the SQN bubble mixer
  • Oxygen generator · built-in
  • Timer controller · sets supply time for each chair

Site preparation

  • Water supply line · mains or purified water line to the unit chairs
  • Power · 220 V outlet
  • Installation space · room for the 600 × 180 × 500 mm main unit

Information needed for a quote

  • Number of chairs · number and layout of unit chairs to connect
  • Water supply method · direct mains, water purifier or independent bottle system
  • Unit chair model · manufacturer and model name
  • Current waterline maintenance · disinfection method and interval, and whether water is tested

From technical consultation to delivery and installation

  1. Inquiry

    Send us the information above via the inquiry form or by phone.

  2. Site check

    We check the water supply line, installation location and power.

  3. Quote & configuration

    We provide a configuration and quote suited to your number of chairs and water supply method.

  4. Delivery & installation

    Delivery takes 3–4 weeks after ordering.

  5. Warranty & service

    The warranty period is 1 year from delivery.

MEDICAL NB FAQ

Answers to key technical and adoption questions when considering MEDICAL NB.

Can we stop our current waterline maintenance?

It is used together with existing infection control procedures.

Flushing before treatment and regular water quality tests continue as before, and the interval for disinfectant use is adjusted based on water test results.

Is the water safe to use as is, since it comes into contact with patients?

No chemical disinfectants are added.

The system uses only water and oxygen. The treated water is supplied to dental unit waterlines, including handpieces, scalers, syringes and rinse cups. Water quality is managed through the clinic's existing testing and maintenance procedures.

How many chairs can be connected?

One unit can serve up to 20 chairs.

Supply time is controlled by a timer; above 20 chairs, the system is divided into zones with two or more units.

Can it be installed on our clinic's unit chairs?

Because it connects to the water supply line, it can be installed on most unit chairs.

Tell us the manufacturer, model and water supply method, and we will confirm the connection method.

By what standard is waterline water quality managed?

Regular tests are based on heterotrophic bacteria counts.

In Korea, ≤100 CFU/mL is recommended for dental unit water, and the US CDC sets ≤500 CFU/mL; testing intervals follow the clinic's infection control procedures.

How do I check the price?

Pricing depends on the number of chairs and configuration and is provided by quotation.

Tell us the number of chairs, water supply method, unit chair model and current waterline maintenance, and we will provide a suitable configuration and quote.

What are the lead time and warranty?

Delivery takes 3–4 weeks after ordering, and the warranty period is 1 year from delivery.

Service requests are accepted via the inquiry form or by phone.

Tell us your number of chairs and water supply method. Tell us the number of chairs, water supply method, unit chair model and current waterline maintenance, and we will provide a suitable configuration and quote.

Request a Quote